Library Contents Search the Library RV Tech Library Help Page Site Map About Us Tiffin RV Network TRVN Classifieds Campground Reviews Photo Gallery TRVN Store Appliances Batteries Boondocking/Dry Camping Chassis Clubs & Forums Electrical Electronics Engines Exterior Maintenance Generators Heating & Air Conditioning Interior Maintenance Misc Items Operating Tips Plumbing Red Bay Safety & Health Storage Supplier Contacts Tires and Wheel Rims Towing Transmissions Weighing |
Troubleshooting
|
PILOT OUTAGE |
|
CONDITION | SOLUTION |
Gas pressure incorrect | Set inlet pressure at a minimum 11" W.C. with two or more appliances running |
Blocked “U” tube | Remove obstruction |
Improper main burner alignment | Re-align main burner and main burner orifice holder and gas valve |
Improper air adjustment | Adjust main burner air shutter approximately 1/4 open |
Weak thermocouple | Replace thermocouple |
Poor pilot flame | Clean or replace pilot orifice |
Weak gas control magnet | Replace gas control |
Defective E.C.O. in control | Replace gas control and check the pilot flame. It should be high enough to engulf the thermocouple at all times |
PILOT OUTAGE WHEN BUTTON OR KNOB IS RELEASED |
|
CONDITION | SOLUTION |
Thermocouple not hot | Hold button or knob for 30 seconds before releasing |
Thermocouple loose | Tighten connection at gas control |
Weak thermocouple | Replace thermocouple |
Weak gas control magnet | Replace gas control |
Defective E.C.O. in control | Replace gas control |
MAIN BURNER WILL NOT IGNITE |
|
CONDITION | SOLUTION |
Blocked main burner orifice | Clean or replace orifice |
Main burner flame spreader mis-alignment | Square flame spreader to end of main burner |
Blocked main burner | Remove blockage |
Improper air adjustment | Adjust main burner air shutter approximately 1/4 open |
Blocked “U” tube | Remove blockage |
Gas control out of calibration | Replace gas control |
ERRATIC MAIN BURNER FLAME |
|
CONDITION | SOLUTION |
Improper gas pressure | Set inlet pressure to a minimum of 11� W.C. with two or more appliances running |
Improper air adjustment | Adjust main burner air shutter approximately 1/4 open |
Partial blockage of main burner | Remove blockage |
Partial blockage of main burner orifice | Clean or replace orifice |
Flame spreader misaligned | Re-align spreader or replace main burner |
Blockage in “U” tube | Remove blockage |
Poor gas supply | Replace gas supply |
Exhaust grille blocked | Remove blockage |
Improper main burner alignment | Re-align main burner, main burner orifice holder and gas valve |
SMOKING AND SOOTING |
|
CONDITION | SOLUTION |
Gas pressure incorrect | Set inlet pressure to a minimum of 11� W.C. with two or more appliances running |
Poor gas supply | Replace gas supply |
Improper pilot flame | Clean or replace pilot orifice |
Improper air adjustment | Adjust main burner air shutter approximately 1/4 open |
Flame spreader mis-aligned | Re-align or replace main burner |
Blocked main burner | Remove blockage |
Improper main burner alignment | Re-align main burner, main burner orifice holder and gas valve |
Blocked “U” tube | Remove blockage |
INSUFFICIENT WATER TEMPERATURE |
|
CONDITION | SOLUTION |
Temperature selector out of place | Re-set to desired position |
Bypass levers improperly positioned | Reposition levers |
Improper air adjustment | Adjust main burner air shutter approximately 1/4 way open |
Partial main burner blockage | Remove blockage |
Improper main burner adjustment | Re-align main burner and main burner orifice |
Flame spreader mis-aligned | Re-align or replace main burner |
Blocked “U” tube | Remove blockage |
Submitted by Mike Sundberg - 3/17/06
The RV Tech Library is brought to you by the TiffinRVnetwork
Absolutely No Affiliation exists between this group and Tiffin Motor Homes Inc or the Allegro Club. This website neither endorses or discourages the use or purchase of a Tiffin product. All references, suggestions, comments, etc. contained herein are the opinions/experiences of the posters and not those of Tiffin Motor Homes Inc. or the website administrators.
|